Performance

1command
2min read
Sheet 27 of 33 · Server Admin

Command/paste reloadIgnitePaste does its heavy work where it costs least: schematic sizes are read off the main thread, pastes are spread over ticks, previews are capped. The settings below are the ones worth knowing on a busy server or with big schematics.

Pasting

Config keypaste.async.blocks-per-tickThe default async path splits a paste into batches of paste.async.blocks-per-tick blocks (1024) per tick: solid blocks first, then torches, plants and other attached blocks. A 20,000-block schematic takes about 20 ticks, one second, with the tick budget spread evenly.

blocks-per-tickGood for
256 to 512Small or crowded servers, or when many players paste at once
1024 (default)Most servers
2048 to 4096Strong hardware and staff pasting large builds

The sync path (async off, or copy-biomes on) is one WorldEdit operation: instant, and on plain WorldEdit a big schematic will hitch the tick. With FAWE installed, WorldEdit operations are FAWE's, which handles large edits better.

A construction places blocks at the pace its duration needs, so it is lighter than an async paste of the same schematic.

Previews

The ghost preview is one display entity per block, shown only to the player and spectating staff.

Config keyoutline.segment-lengthThe outline costs a few dozen entities at most. outline.segment-length splits very long edges so they render from far away; raising it means fewer entities on huge boxes.

Workers

Config keyconstruction.workers.max-countEach worker is one entity with no AI, placed and moved by the plugin. construction.workers.max-count (12) is the most a single build can hire. With many builds running at once, lower it: the build still lands on time, workers just place a few blocks per swing when the crew is capped.

Storage

YAML suits one server with a moderate number of players. With thousands of players and many schematics, SQLite keeps writes small. MySQL is for sharing data between servers. All three load everything on start and keep it in memory.

Index and reload

Command/paste reloadIndexing reads file names and sidecars only; schematics are loaded on first use and cached, and sizes are read in the background when the selector first shows them. /paste reload clears the caches and re-indexes, so the next selector opens and pastes read the files again. Reload during a quiet moment on servers with hundreds of large schematics.

Loading the index

Enter openUp Down moveEsc close