FAQ & Troubleshooting
Fileconfig.jsonFilepremium-hosts.jsonReal failure modes, with the message the tool prints and what fixes it. Questions before buying are answered on the product page.
License
CI fails with "Not licensed" and exit code 3
The job has no key. Store the license key as a secret and pass it as ITT_LICENSE to the step that runs the jar. It takes the license's shared CI slot, not one of your computers. See License.
"This key is already active on all the computers it covers"
Every machine slot is in use. On a computer you no longer use, open Settings > License and press Deactivate this computer, or free the slot from the license page (Lost key or new computer on the key screen).
The tool says it keeps working offline until a date
The license server could not be reached. The last activation keeps working for 7 days; connect once before the date and it renews by itself. A computer that was never activated cannot start offline.
Does run or call need a key?
No. The command line client talks to a tool that already runs, and that tool holds the license.
Starting
"IgniteTestTool is already running for <folder>"
Only one tool runs per data folder. Close the other one, or start the second with its own --data-dir. A headless start exits with code 2 here.
A second server will not start: "Port 25565 is already in use" or "World 'world' is locked"
Config keysession.lockThe server guard found a server on that port, or a world whose session.lock is held. Stop the other server, or check Server > Ghosts for one left over from a crash.
Processes from the last session are still running
Fileconfig.jsonAfter a crash the tool finds them by PID and start time and asks what to do. survivorPolicy in config.json (Settings > Safety > Leftovers from a crash) makes it kill or ignore them without asking. See Process Safety.
"No server folder set" or "No client launch file set"
serverDir and clientLaunchJson are empty until you pick them. Set the server folder on Settings > Test server and the launch file on Settings > Game client. A takeover needs no launch file, it downloads its own client. An empty Java program runs the server on the Java the tool runs on.
Settings will not save
The status line names the first value that cannot work, with its key in brackets, for example Mod camera port and API port are both 8766, give the mod its own (modCameraPort). Fix it and Save lights up. See Configuration.
Bots
"server 127.0.0.1:25565 is offline, start it first"
Nothing answers on that address. Start the server (Start server on Live), or point the bots at the right host and port in Settings > Bots or the Bots header.
The bot is kicked as soon as it joins
- An offline bot needs
online-mode=false. For an online-mode server add a premium account and join withaccount=. - A backend behind Velocity with modern forwarding refuses a direct join unless the bot knows the secret. Set Settings > Bots > Velocity forwarding secret, see Proxies & Transfers.
- The kick reason shows on the bot's screen, with Join again.
"premium bots on <host> need a one-time confirmation"
Filepremium-hosts.jsonPremium bots joining a host that is not local ask once. Confirm in the window, or pass confirmHost=1 on the API (confirmHost: true in a scenario join). The answer is kept in premium-hosts.json.
Chat and /msg are refused on my server
The server has enforce-secure-profile=true. Only premium bots sign chat; offline bots get plain chat refused there. See Premium Accounts.
My server is older than 1.21.4
Bots are checked on 1.21.4 to 1.21.11. Older servers are untested because the bot code expects 1.21 features. See Limitations.
Server agent and RCON
"agent not reachable at http://127.0.0.1:8768 (is IgniteTestAgent installed?)"
server, assertServer and /server/... need IgniteTestAgent in the server's plugins. Install it from the Agent page, with --install-agent in CI, or /server/install-agent?dir=<server>/plugins, then restart the server. The API answers 502 until it is up. See Server Agent.
On a server on another machine, check in this order:
- The SSH tunnel is still open.
ssh -N -L 8768:127.0.0.1:8768 user@hostmust keep running while you test. - Fileplugins/IgniteTestAgent/config.ymlWithout a tunnel,
bindinplugins/IgniteTestAgent/config.ymlis0.0.0.0, not the default127.0.0.1, and the server was restarted after the change. - The firewall lets your IP in on port 8768.
- Settings > Agent address points at the right place:
http://127.0.0.1:8768with a tunnel,http://host:8768with an open port.
See Remote server.
"rcon login refused, wrong password"
Config keyrcon.passwordFileserver.propertiesrconPassword in Settings does not match rcon.password in the server's server.properties. In CI pass --rcon-password.
HTTP API and command line
401 "missing or wrong token"
Config keyapi-token.txtThat route changes things and needs the token: the X-ITT-Token header or token=, from api-token.txt in the data folder or ITT_API_TOKEN. See HTTP API.
403 "requests from web pages are refused"
The request carried an Origin header, which browsers add on cross-site calls. The API only answers scripts, curl and the tool's own browser panel. A Host that is not 127.0.0.1, localhost or [::1] is refused the same way.
"no IgniteTestTool on port N for <folder>"
The command line client did not find a running tool for that data folder. Start one with --headless --data-dir <folder>, or pass the same --data-dir the tool runs with. The client exits with code 2.
call /rcon turns into a Windows path in Git Bash
Git Bash rewrites arguments that start with /. Leave the slash out: call rcon c="list".
A filming route answers 401 after an update
/film, /film/coverage, /shoot, /sequence, /autofilm, /produce, /render, /edl, /job/submit, /scene/stage, /scene/act, /scene/choreo and /release need the token now, like /takeover. Send X-ITT-Token. See HTTP API.
GET /coverage answers "coverage needs the subject x, y and z"
That was the filming route sitting on /coverage in older builds. Filming coverage is /film/coverage now and /coverage is command coverage again.
Scenarios
A scenario passes once, then fails on the next run
It leans on state from the run before: a full inventory, a player at max level, a mob that walked away. fresh: true on join (or freshPlayers: true at the top) resets the player through the agent, and a checkpoint restores plugin data before the file.
title: zombies should not match ᴢᴏᴍʙɪᴇꜱ, but it does
Titles, names, lore and chat are matched with small caps read as plain letters, on purpose. Write a regex that needs the exact characters when it matters.
The cache skipped a file I expected to run
A file is skipped when its text, includes, the jars and the configs it ran against are the same as at its last pass. Something it depends on outside the server's configs is not part of that: add it with cache: {inputs: [...]}, or keep the file out with cache: false. See Result Cache.
A takeover step fails in CI
The runner has no display. Takeovers need a self-hosted Windows runner logged in as a user, not a service or a hosted runner.
Captures and filming
"the client window is minimized"
Captures read the window's picture, which a minimized window does not have. Restore it; it may sit behind other windows.
"<bot> did not become ready to film within N s"
The takeover client did not reach the world with a visible window in filmTakeoverTimeoutSeconds (150). The first takeover downloads the client, so try again once it is in the cache, or raise the timeout.
"could not start ffmpeg"
The built-in recorder needs ffmpeg. Install it on the PATH or set the ffmpeg program on Settings > Filming (ffmpegPath).
"recorder=obs needs obsScript, the OBS websocket control script, in Settings > Filming"
The call or filmRecorder asks for OBS and no obsScript is set. Leave recorder out for the built-in recorder, or set obsScript to your OBS control script; it does not ship with the tool. The call stops before anything is staged. See Filming.
"drive must be cine, keys, sendinput or mod" or "recorder must be internal or obs"
A typo in drive= or recorder=. Older builds filmed with cine and the built-in recorder without a word, now the call says so.
"no render kit set: /render and /produce run build.cjs from a shorts render kit with node"
The render kit does not ship with the tool. Set renderKitDir on Settings > Auto director, or pass kitDir=. With could not start node install Node.js or set nodePath. See Auto Director.
The mod camera does not answer
Fileconfig/ignitetestcamera.propertiesmodCameraPort (8769) and the API port must differ. The tool writes the port into the client's config/ignitetestcamera.properties on every takeover with modCamera on, and warns on start when the API runs on the same port. A config from 1.3.0 with 8767 moves to 8769 by itself.
Shader footage is choppy
The built-in recorder grabs the window with PrintWindow, which manages only a few frames a second on a shader window at full size. Lower scale, or record with OBS.