Installation

2files
1figure
3min read
Sheet 2 of 47 · Getting Started

Filesconfig.json · workflow.json

Requirements

RequirementNeeded for
Windows 10 or 11Everything
LinuxBots, scenarios, CI mode, the API and the command line client. The window, takeovers, the job object and DPAPI are Windows only
JDK 21Everything
A server on 1.21.4 to 1.21.11The bots. See Bots for how versions are picked

Start it

  1. Put the jar somewhere

    Config, accounts and caches do not go next to it but into the data folder, %LOCALAPPDATA%\IgniteTestTool by default.

  2. Start the window

    Run java -jar IgniteTestTool-1.3.0.jar. The window opens with the HTTP API on.

  3. Enter the license key

    Config keylicense.keyThe first start asks for the key from your purchase email. It is checked against the license server, then kept in license.key in the data folder, and the computer takes one of the key's machine slots. See License & Machine Slots.

  4. Start here

    A first start with no scenarios opens the Start here sheet, which walks through the server, a bot and a first recording. See Quick Start.

  5. Point it at Java and the server

    Open Settings and fill in the server folder and the server jar. The Java program can stay empty, the server then runs on the Java the tool runs on. Start server and Deploy also ask for the folder in place when it is not set yet.

Run

java -jar IgniteTestTool-1.3.0.jar                              # GUI with the API on
java -jar IgniteTestTool-1.3.0.jar --headless --api-port 8767   # API only
OptionMeaning
--headlessNo window, API only
--api-port <port>Port for the HTTP API, default 8766
--data-dir <dir>Where config, accounts and caches live. Default %LOCALAPPDATA%\IgniteTestTool
--config <file>Use a different config.json

ITT_DATA_DIR, ITT_CONFIG and ITT_API_PORT stand in for the three options when they are not on the command line, ITT_API_TOKEN for the token file and ITT_LICENSE for the saved key.

Only one instance runs per data dir. In headless mode, stop it with GET /shutdown. --headless needs a license too: the key saved by the window, or ITT_LICENSE; without one it exits with code 3.

A path argument may hold any character. Windows hands the JVM its arguments in the ANSI code page, which turns a ⇒ into ?; the tool reads them from the real command line instead.

Two other ways to start the jar:

ArgumentWhat happens
--run-scenario or --crawl, anywhere on the command lineSwitches to CI mode, which has its own options
run, check, last, call, panel, guide, usage, coverage as the first argumentTalks to a tool that is already running and needs no license key. See Short Loop & Result Cache

The data folder

Fileconfig.jsonEverything the tool keeps lives in the data folder: %LOCALAPPDATA%\IgniteTestTool on Windows, ~/.ignitetesttool on Linux, or what --data-dir or ITT_DATA_DIR says. That covers config.json, the license key, the API token, premium accounts, caches, histories, reports and the takeover client. Configuration lists every file in it.

Configuration

Fileconfig.jsonFileworkflow.jsonconfig.json in the data folder holds the paths and defaults, workflow.json the scenario folder, deploy and schedule. The Settings screen edits the first, Deploy and Schedule the second, so there is rarely a reason to open them. Every key and its default is on Configuration.

Settings writes config.json in the data folder.
Settings on the Test server group: server folder, server jar file, memory, stop timeout and Java program

Loading the index

Enter openUp Down moveEsc close